How to use UPS to read input voltage on reComputer r1000
Introduction
This wiki article primarily explains how to install the UPS module on the reComputer R10 and R11 series and use the UPS to read the input voltage.
Hardware Preparation
reComputer R1000 | UPS model |
---|---|
![]() | ![]() |
Note Please refer to this link to install the UPS on the R1000.
Software prepare
Step 1: Check UPS module
sudo apt update
sudo apt install i2c-tools
sudo i2cdetect -y 6

Step 2: Download repository from GitHub
git clone https://github.com/Seeed-Projects/Read-UPS-input-voltage.git
cd Read-UPS-input-voltage
sudo apt update
sudo apt install python3-smbus
Step 3: Start monitoring voltage
python -m venv .venv --system-site-packages && source .venv/bin/activate
python read_voltage.py